HAS anyone ever run a PMG 132 in reverse direction at full voltage?

I'm thinking of building a bike running 2 PMG 132's with the output shafts opposing each other. This means hat one will spin in the opposite direction to the other. I understand that these motors are timed, but has hanyone ever run theirs in the reverse direction and had any major problems ???

:)

Patrick
Offline
Last seen: 10 years 2 months ago
Joined: Tuesday, November 21, 2006 - 17:31
Points: 55
Re: HAS anyone ever run a PMG 132 in reverse direction at full v

Yes, they have. The usual problem is that they burn up.

Perms in reverse have to be limited to 48 volts, and they should be re-timed for the reverse direction.