Lepton Oxygen scooter repair

Hi All,

Does any one have any experience repairing a Lepton Oxygen scooter that is displaying a error code of 11 and/or 12? Any advice would be greatly appreciate.

Thanks,
Lynne

before comments

Comments

From the manual:

Error 11: Processor Error No signal from Hall Sensor

Wrong wiring of Hall Sensor on the
break of wiring
Break of Hall Sensor
Problems with electronic card of control

Error12: Tuned of motor Wrong sequence of configuration of Hall Sensor (Yes, that really is how it reads, I'm afraid.)

Wrong wiring of Hall Sensor on the
break of wiring
Break of Hall Sensor
Problems with electronic card of control

I don't know how to fix it, but it looks like you either have a problem with a broken wire to the hall sensors in the motor, one or more sensors going bad (these sensors are needed to help the controller run the motor) or a bad "card of control" which may refer to the security key or to a part of the controller - I don't honestly know. If you want the manual, which is limited in usefulness, email me at leftiebiker [at] gmail.com with "Lepton" in the subject line.